Model NO.: MED0001
Medical Devices Ad. Approval No.: Ts2210g40-2017
Medical Device Regulatory Type: Special Equipment
Medical Devices Reg./Record No.: Ts2210g40-2017
Working Pressure: 150bar
Low Temperature: -60c
Trademark: ASF
Transport Package: Carton/Wooden Case/Pallet
Specification: GB, EN, DOT, ISO
Origin: Tieling, Liaoning Province. China
HS Code: 76130010
Model NO.: MED0001
Medical Devices Ad. Approval No.: Ts2210g40-2017
Medical Device Regulatory Type: Special Equipment
Medical Devices Reg./Record No.: Ts2210g40-2017
Working Pressure: 150bar
Low Temperature: -60c
Trademark: ASF
Transport Package: Carton/Wooden Case/Pallet
Specification: GB, EN, DOT, ISO
Origin: Tieling, Liaoning Province. China
HS Code: 76130010
Service pressure 150bar. Made of Aluminum alloy 6061. Keep supplying medical Oxygen from 2.3hours to 20hours.Medical portable Oxygen gas cylinder sizes:
. Advantage :High standard for safety.Strict test for every cylinder.   Â
          Highly anti-corrosion. High strengthy thickness.
          Perfect treatment for surface interior and exterior.
        Â
. Valve fitted: CGA serials, QF serials or upon customers' demand.
. Carrying bag/shoulder bag/carrying kit available.
. Delivery time: Â 6 days to 30 days upon deposit.
Â
Specification | Outer Diameter | Water Volume | Length | Weight | Â Oxygen support | Working Pressure |
 | mm | liter | mm | kg | minute | bar |
LW-89-1.0-15-H | 89 | 1 | 269 | 1.2 | 140 | 150 |
LW-108-1.4-15-H | 108 | 1.4 | 264 | 1.6 | 200 | 150 |
LW-120-2.0-15-H | 120 | 2 | 320 | 2.7 | 280 | 150 |
LW-120-2.8-15-H | 120 | 2.8 | 398 | 3.2 | 380 | 150 |
LW-120-3.2-15-H | 120 | 3.2 | 437 | 3.5 | 448 | 150 |
LW-140-4.0-15-H | 140 | 4 | 420 | 4.2 | 600 | 150 |
LW-140-6.0-15-H | 140 | 6 | 580 | 5.9 | 790 | 150 |
LW-140-8.0-15-H | 140 | 8 | 741 | 7.6 | 1200 | 150 |
LW-159-10.0-15-H | 159 | 10 | 730 | 8.8 | 1200 | 150 |
Type of valve | Features |
CGA870 post valve with toggle |
The most convenient to turn on and off. Don't require wrench. Adopted for Oxygen cylinder: M2, M4, M6, ML6, M9, D, Jumbo D and E Â |
CGA870 post valve |
No Toggle. Requires wrench. Adopted for Oxygen cylinder: M2, M4, M6, ML6, M9, D, Jumbo D and E Â |
CGA540 | Adopted for Oxygen cylinder of large capacity: MM, M60, HK |
Medical portable Oxygen gas cylinder sizes:
. Advantage :High standard for safety.Strict test for every cylinder.   Â
          Highly anti-corrosion. High strengthy thickness.
          Perfect treatment for surface interior and exterior.
        Â
. Valve fitted: CGA serials, QF serials or upon customers' demand.
. Carrying bag/shoulder bag/carrying kit available.
. Delivery time: Â 6 days to 30 days upon deposit.
Â
Specification | Outer Diameter | Water Volume | Length | Weight | Â Oxygen support | Working Pressure |
 | mm | liter | mm | kg | minute | bar |
LW-89-1.0-15-H | 89 | 1 | 269 | 1.2 | 140 | 150 |
LW-108-1.4-15-H | 108 | 1.4 | 264 | 1.6 | 200 | 150 |
LW-120-2.0-15-H | 120 | 2 | 320 | 2.7 | 280 | 150 |
LW-120-2.8-15-H | 120 | 2.8 | 398 | 3.2 | 380 | 150 |
LW-120-3.2-15-H | 120 | 3.2 | 437 | 3.5 | 448 | 150 |
LW-140-4.0-15-H | 140 | 4 | 420 | 4.2 | 600 | 150 |
LW-140-6.0-15-H | 140 | 6 | 580 | 5.9 | 790 | 150 |
LW-140-8.0-15-H | 140 | 8 | 741 | 7.6 | 1200 | 150 |
LW-159-10.0-15-H | 159 | 10 | 730 | 8.8 | 1200 | 150 |
Type of valve | Features |
CGA870 post valve with toggle |
The most convenient to turn on and off. Don't require wrench. Adopted for Oxygen cylinder: M2, M4, M6, ML6, M9, D, Jumbo D and E Â |
CGA870 post valve |
No Toggle. Requires wrench. Adopted for Oxygen cylinder: M2, M4, M6, ML6, M9, D, Jumbo D and E Â |
CGA540 | Adopted for Oxygen cylinder of large capacity: MM, M60, HK |
Sophora Flavescens Extract,Natural Pyrethrin Extract,Celastrus Angulatus Extract,Allicin Aged Garlic Extract
Xi'an XJeson Biotech Co., Ltd , https://www.xjesonbio.com