- Model NO.: HD-9000B
- Certification: CE
- LCD Display: With LCD Display
- Dimensions: L140xw360xh260
- Chargingtime: Maximum 8 Seconds to 360joules
- Vehicle Voltage: DC12V
- Measurement Range: 20~45oc
- Specification: CE
- HS Code: 90189090
- Type: Defibrillator
- Group: All People
- Mainunit: Portable
- Weight: 13kg
- AC Power Supply: 110V, 60 Hz /220V,50 Hz
- Battery Type: Rechargeable Lead-Acidbattery
- Trademark: everich
- Origin: China
HD-9000BÂ Defi-monitor
Physicalcharacteristics:
Dimensions | 410x360x260 |
Weight | 13kg |
Defibrillator type | Manual, Synchronized, Asynchronized |
AC Powersupply   | 110V, 60 Hz /220V,50 Hz  |
VehicleVoltage  | DC12V |
Temperature Measurement range | 20~45ºC |
Mainunit:Desktop
Dimensions:L410xW360xH260
Weight:13kg
Technical specifications  Â
DEFIBRILLATOR.
      (1) Defibrillator type                    Manual, Synchronized, Asynchronized,  Â
      (2)  Out putwaveform                  Monophasictechnology                                                                           Â
      (3)  Energyaccuracy                   ∠+1%
   (4)  Energyselection          0,20,50,100,160,250,300,360 joule (nominal at aresistance of 50)
      (5)  Chargingtime                     Maximum 8 seconds to 360Joules
   (6)  Standard Adult/PediatricPaddles   Reusable extermal adultpaddles(pediatric paddles integrated)           Â
.Powerrequirements.
      (a)  AC Powersupply                  110V, 60 Hz /220V,50 Hz Â
   (b)VehicleVoltage          DC12V
InternalBatteryBackup
             (1) Batterytype           Rechargeable lead-acidbattery
             (2)  Chargingtime              Time-Minimum of 4 hours for fullcharging   Â
          (3) Batterycharging     During AC Power Supplyoperation of the device.
(4) Charging/LowBatteryIndication     RedLED               Â
(5) Battery Capacity       100% of thebattery will provide 120 mins of monitoring; and 30 discharges at360 joules.
Display
-LEDDimensions    10'diagonal
-Type                 High resolution true-color graphic LED
ECG
ECG lead:I, II, III, AVR, AVL, AVF,V1~V6, GND
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protection: With stand 4000vAc/50Hzvoltage in isolation and work against electrosurgical knife and defibrillation
Respiration
Measurementmethod: Thoracic impedance
NIBP
Working mode:Manual/Automatic/stat(5 minutes)
Method: Automatic oscillation
Cuff type:standard Adult; optional Pediatric/Neonatal
Temperature Measurement range 20~45ºC
Resolution: 0.1ºC
Â
Pulse Oximetry(spO2)
Display:spo2 value, pulse histogram,waveform,Pulse
Range:Â 0~99%for adult,pediatric andneonatal patients
Probe:standard adult fingerclip
optionalpediatric Y-type clip and neonatal wrap
PulserangeÂ
Pulse range:0-255bpm
Standardparameter & configuration
 ECG/RESP,/SPO2,/TEMP,/PR,/NIBP/DEFIBRILLATOR
Optionalparameter
Recorder
Â
Vine Tea Extract,Bearberry Extract,Artemisia Annua Extract
Standard Herbal Extract Co., Ltd. , http://www.chaoshenbao.com