The use of standard constant temperature and humidity chamber and related technical parameters

The use of standard constant temperature and humidity chamber and related technical parameters

The purpose of the standard constant temperature and humidity chamber: (PCB/FPC industry-specific) is to simulate the product under the combination of temperature and humidity in the climatic environment (high and low temperature operation & storage, temperature cycle, high temperature and high humidity, low temperature and low humidity, condensation test.. , etc.), to detect whether the adaptability and characteristics of the product itself have changed. ※ It is required to meet the requirements of international standards (IEC, JIS, GB, MIL...) to achieve international measurement procedure consistency (including test procedures, conditions, methods)

Technical parameters of standard constant temperature and humidity chamber

Models

BYH-150

BYH-225

BYH-408

BYH-800

BYH-1000

Inside Dimensions
W x D x H cm

50X50X60

50X60X75

60X80X85

100X80X100

100X100X100

Outside Dimensions
W x D x H cm

115X75X150

115X85X165

130X105X170

165X105X185

170X125X185

Precool/Preheat Range

-70°C, -40°C, -20°C, 0°C to +150°C

Shocking Range

20%RH ~ 98%RH

Time Range

0 hour 1 min to 9999 hour 59 min/segment

Resolution

±0.01°C/min, ±0.1%RH/min

Control Constancy

±0.5°C, ±2.0%RH

Temperatureuniformity°C

±1.0°C (-40°C~100°C)/±2.0°C (-40°C~+70°C; +100.1°C~+150°C)

Humidity uniformity%RH

±3.0% RH

Micro Controller

BYH-600

* The above specifications are for reference only and are subject to change without notice.

Standard constant temperature and humidity chamber equipment features

â—† The same volume is subject to a large storage area and load heat

â—† Adopting new American PWM refrigerant control technology to achieve low temperature energy saving operation

â—† Prevent test items from condensation control conditions

â—† Communication configuration RS232 interface and USB storage download function

â—† Machine multi-alarm monitoring, configure wireless remote alarm function

â—† The safest water system and reclaimed water circulation system

◆ Humidity effect can reach 15 °C / 5% RH performance, dehumidification speed

â—† Prevents static electricity consumption and achieves the best performance in the same industry

Refrigeration advantages

Low-temperature control mode of traditional equipment: cooling compressor start-stop control temperature (large temperature fluctuation, seriously affecting compressor life, technology that has been eliminated) constant operation of refrigeration compressor + heating PID control (causing cooling capacity and heating phase offset to achieve temperature dynamic balance Waste a lot of power) New PWM cold control technology to achieve low-temperature energy-saving operation: low-temperature working state, the heater does not participate in the work, control the refrigerant flow and flow direction of the refrigeration unit through PWM technology, to the refrigeration pipeline, cold bypass pipeline, heat The three-way flow adjustment of the bypass pipe enables automatic constant temperature to the working chamber. This method can reduce energy consumption by 40% under low temperature conditions.

AM Hard Tag

Eas anti-theft antenna is mainly suitable for large supermarkets, shopping malls, bookstores, audio stores with Security hard tags, rf soft label, AM lable,Pin and Lanyard, eas detacher, Hook Lock ,EAS Self Alarm Tag, EAS Safer Box,etc.

Am Hard Tag,Rf Pencil Security Tag,Eas Security Hard Tag,Lanyard Hard Tag

Wenzhou Boshine Electronic Security Co. Ltd  , https://www.boshine.com